EasyManua.ls Logo

KEB F6 - Page 143

KEB F6
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Descriptions
© 2024 KEB America, Inc.
143
8.7.3.3 Emergency (Intermediate Speed 3) Profile Rate Settings
LS40 Acceleration Emergency
Acceleration rate for Emergency Profile (Intermediate Speed 3 or Emergency Profile
input).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
3.7
-
m/s^2
0.45
Basic
0.3
12.0
ft/s^2
-
1.5
LS41 Start Jerk Emergency
Start Jerk rate into acceleration for Emergency Profile (Intermediate Speed 3 or
Emergency Profile input).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.45
Basic
0.3
32.0
ft/s^3
-
1.5
LS42 Acceleration Jerk Emergency
Acceleration Jerk rate into speed for Emergency Profile (Intermediate Speed 3 or
Emergency Profile input).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.45
Basic
0.3
32.0
ft/s^3
-
1.5
LS43 Deceleration Emergency
All speeds will use the LS43-45 deceleration and jerk settings for the Final Stop
portion of the profile. Additionally, for analog and serial speed control modes, if the
direction is dropped before zero speed has been reached, these rates will be used
for the final deceleration.
Deceleration rate for Emergency Profile (Intermediate Speed 3 or Emergency Profile
input).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
3.7
-
m/s^2
0.45
Basic
0.3
12.0
ft/s^2
-
1.5