LL05 SPI
Stationary Pole Identification. Learns the motor pole position (encoder position) without
movement, for synchronous motors. Refer to Encoder Learn section, pg. 71 for
procedure.
If the encoder A/B channel phasing is subsequently swapped in LE03, the SPI
procedure will need to be performed again.
USER: Run empty car UP on
Inspection Speed
STATUS: Determining encoder
pole offset
FAILURE: Speeds not correct,
verify encoder
PPR/Signal/Mounting
STATUS: Motor phasing incorrect,
swapping encoder phases, run the
car UP again
USER: Did the elevator travel UP?
STATUS: Reversing motor
direction, run the car UP again
FAILURE: Encoder error detected,
verify encoder
PPR/Signal/Mounting
FAILURE: Minimum measurement
speed not reached, increase
speed, run the car UP again
SUCCESS: SPI complete, do
Encoder Synchronization next
Cannot start tune because another
tune mode is already active
ERROR: Tune Motor with LL01 first