Parameter Descriptions
© 2024 KEB America, Inc.
211
DG63 NTSD Speed 1 Up
This is written with the current speed of the system. It is compared with TS03 NTSD 1
Speed Up. It will then slow down the elevator to match the desired speed set in TS02
(NTSD Target Speed).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
-
m/s
0
Basic
0
1970
ft/min
-
0
DG64 NTSD Speed 2 Up
This is written with the current speed of the system. It is compared with TS04 NTSD 2
Speed Up. It will then slow down the elevator to match the desired speed set in TS02
(NTSD Target Speed).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
-
m/s
0
Basic
0
1970
ft/min
-
0
DG65 NTSD Speed 3 Up
This is written with the current speed of the system. It is compared with TS05 NTSD 3
Speed Up. It will then slow down the elevator to match the desired speed set in TS02
(NTSD Target Speed).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
-
m/s
0
Basic
0
1970
ft/min
-
0
DG66 NTSD Speed 1 Down
This is written with the current speed of the system. It is compared with and TS06 NTSD
1 Speed Down. It will then slow down the elevator to match the desired speed set in
TS02 (NTSD Target Speed).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
m/s
0
Basic
0
1970
ft/min
0