Parameter Descriptions
212
© 2024 KEB America, Inc.
DG67 NTSD Speed 2 Down
This is written with the current speed of the system. It is compared with TS07 NTSD 2
Speed Down. It will then slow down the elevator to match the desired speed set in TS02
(NTSD Target Speed).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
m/s
0
Basic
0
1970
ft/min
0
DG68 NTSD Speed 3 Down
This is written with the current speed of the system. It is compared with TS08 NTSD 3
Speed Down. It will then slow down the elevator to match the desired speed set in TS02
(NTSD Target Speed).
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
-
m/s
0
Basic
0
1970
ft/min
-
0
DG69 Total Runs
Displays the total number of runs.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
4294967295
-
-
0
Basic
DG70 Calculated Motor Pole
Displays the calculated motor pole:
# of Motor Poles = Rated Frequency (Hz) x 120 / Rated Speed (rpm)
The number of motor poles should calculate to a whole even number.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
50000
-
-
0
Basic

Table of Contents