Parameter Reference
264
© 2024 KEB America, Inc.
Para.
Name
Adr
Motor Type
Setting Options
Num
Range
Units
Default
Pass
Level
Ind.
PM
Min
Max
Imp.
Met.
US02
System Units
0x0282
RW
RW
System Units
-
0
1
-
-
1
Basic
m/sec
0
-
-
-
-
-
-
ft/min
1
US03
Motor Type
0x0283
RW
RW
Motor Type
-
0
1
-
-
1
Basic
Induction
0
-
-
-
-
-
-
PM synchronous
1
US04
Control Type
0x0284
RW
RW
Control Type
-
0
6
-
-
1
Basic
Digital speed selection
0
-
-
-
-
-
-
Binary speed selection
1
Absolute analog speed
2
Bi-polar analog speed
3
Serial Speed DIN66019 serv.49
4
Serial Speed DIN66019 serv.50
5
Serial binary speed DIN66019 serv.50
6
US05
Load Configuration
0x0285
RW
RW
Load Configuration
-
0
99
-
-
0
Basic
Not configured
0
-
-
-
-
-
-
Configuration OK
1
Load configuration
2
Reserved
3
Write config. to flash
4
Read config. from flash
5
Reserved
6
Reserved
7
Create OEM defaults
8
Restore OEM defaults
9
Restore KEB defaults
10
Config File Missing/Error
99
Backup File
-
Missing Parameter Backup
128
No File Load Error
0
US06
Contract Speed
0x0286
RW
RW
-
-
0
8.1
m/s
0
Basic
0
1600
ft/min
0
Basic
US07
Date Time
0x0287
RW
RW
-
-
0
-1
-
-
0
Basic

Table of Contents