EasyManua.ls Logo

KEB F6 - Page 265

KEB F6
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Reference
© 2024 KEB America, Inc.
265
Para.
Name
Adr
Motor Type
Setting Options
Num
Range
Units
Default
Pass
Level
Ind.
PM
Min
Max
Imp.
Met.
LI02
Digital Input Filter
0x0382
RW
RW
-
-
10
100
ms
-
20
Basic
LI03
Speed Input Decoding
0x0383
RW
RW
Binary Speed Selection
-
0
28
-
-
0
Basic
B(Level - Correction - Inspection)
0
-
-
-
-
-
-
B(Inspection - Level - Correction)
1
B(Level - Correction - High)
2
Decode with Li16
3
Digital Speed Selection
-
D(Level - Correct. - High - Inspect.)
0
D(Level - High - Inspect. - Interm.)
4
D(Inspect. - Level - High - Interm.)
8
D(Level - Int2. - High - Inspect.)
12
D(Level - High - Inspection - Correction -
Intermediate 1)
16
LI04
Input 1 Function
0x0384
RW
RW
Input Function
-
0
33
-
-
0
Basic
No function
0
-
-
-
-
-
-
UPS Operation
1
Reduced torque
2
UPS + Reduced torque
3
Emergency Profile
4
UPS + Emergency Profile
5
Red. torq. + Emerg. Prof.
6
UPS + Red. torq. + Emerg. Prof.
7
Emergency Power Speed
8
UPS + Emerg. Gen. Spd
9
Red. torq. + Emerg. Gen. Spd
10
UPS + Red.torq. + Emerg.Gen.Spd
11
Emerg. Prof. + Emerg. Gen. Spd
12
UPS + Emerg. Prof. +Emerg. Gen. Spd
13
Red. torq. + Emerg. Prof. + Emerg. Gen. Spd
14
UPS + Red.torq. + Emerg.Prof. +
Emerg.Gen.Spd
15
Fault reset
16
External fault
17
Reserved
18
Main contactor check
19
Earthquake speed
20
Emergency Slowdown
21
Reserved
22
Reserved
23
Reserved
24
Up direction
25
Down direction
26
Speed Selection
27
ETS (emergency terminal slowdown)
28
NTS1 (normal terminal slowdown)
29
NTS2 (normal terminal slowdown)
30
NTS3 (normal terminal slowdown)
31
Inspection Speed
32
Regen Fault
33
Reserved
34
Reserved
35
LI05
Input 2 Function
0x0385
RW
RW
Same as LI04
"
0
33
-
-
27
Basic

Table of Contents