Parameter Reference
© 2024 KEB America, Inc.
267
Para.
Name
Adr
Motor Type
Setting Options
Num
Range
Units
Default
Pass
Level
Ind.
PM
Min
Max
Imp.
Met.
LM12
Motor Temp. Sensor
(E.dOH)
0x068C
RW
RW
Sensor Type
-
0
5
0
Basic
OFF - No Error
0
-
-
-
-
-
-
NC switch or PTC sensor
1
KTY 84/130 sensor
2
KTY 83/110 sensor
3
PT1000 sensor
4
Encoder
5
LM20
Motor Ls
Motor Ls
0x0694
RW
-
-
-
0.01
655.35
mH
-
10
Basic
Motor Lsq
-
RW
0.01
655.35
mH
10
LM21
Motor Rs
0x0695
RW
RW
-
-
0.001
65.535
Ohm
-
1
Basic
LM22
Motor Rr
0x0696
RW
-
-
-
0.001
65.535
Ohm
-
1
Basic
LM23
Motor Lm
0x0697
RW
-
-
-
0.1
3276.7
mH
-
100
Basic
LM24
Field Weakening Corner
0x0698
RW
-
-
-
0
500
%
-
200
Basic
-
RW
0
500
%
300
LM25
Field Weakening Speed
0x0699
RW
-
-
-
1
4000
1/min
-
1000
Basic
LM26
Motor Ls Max
0x069A
-
RW
-
-
0.01
500
mH
-
0.01
Basic
LM27
Motor Inductance Mode
0x069B
-
RW
Mode
-
0
2
-
2
Basic
Amplitude Modulation
0
-
-
-
-
-
-
di/dt (Five Step)
1
Auto Select
2
LM30
Motor Control
0x069E
RW
-
Motor Model
-
0
31
-
-
2
Basic
OFF
0
-
-
-
-
-
-
Motor Model On
1
Vmax regulation
-
OFF
0
Vmax Regulation
2
Flux Control
-
OFF
0
Flux Control
4
Flux Proofing
-
OFF
0
Flux Proofing
8
Zero spd model
-
OFF
0
Zero spd model
16
-
RW
Motor Model
-
0
3
-
-
2
Basic
OFF
0
-
-
-
-
-
-
Motor Model On
1
Vmax regulation
-
OFF
0
Vmax Regulation
2
LM31
Vmax Regulation
0x069F
RW
RW
-
-
0
110
%
-
97
Basic
LM32
KP Current
0x06A0
RW
RW
-
-
0.01
655.35
-
-
1
Basic
LM33
KI Current
0x06A1
RW
RW
-
-
0.01
655.35
-
-
0.1
Basic
LM34
KP Current d - axis
0x06A2
RW
RW
-
-
0.01
655.35
-
-
1
Basic
LM35
KI Current d - axis
0x06A3
RW
RW
-
-
0.01
655.35
-
-
0.1
Basic