Method of Control
48
© 2024 KEB America, Inc.
LI03 = D(Level - High - Inspect. - Interm.) [Leveling at start], NUM = 4
US04 = 0
Digital Speed
Selection
Parameter
Control Inputs
I1
I2
I3
I4
S ZERO
-
0
0
0
0
S LEVELING
LS01
1
0
x
x
S HIGH SPEED*
LS02
1*
1
x
x
S HIGH SPEED
LS02
0
1
x
x
S INSPECTION
LS03
0
0
1
x
S INTERMEDIATE 1
LS05
0
0
0
1
*Valid only at start (during deceleration, once leveling speed is reached it is not
possible to accelerate up to high speed again until after zero speed has been
selected)
LI03 = D(Inspect. - Level - High - Interm.), NUM = 8
US04 = 0
Digital Speed
Selection
Parameter
Control Inputs
I1
I2
I3
I4
S ZERO
-
0
0
0
0
S LEVELING
LS01
0
1
x
x
S HIGH SPEED*
LS02
0
0
1
x
S INSPECTION
LS03
1
x
x
x
S INTERMEDIATE 1
LS05
0
0
0
1
LI03 = D(Level - Int.2 - High - Inspect), NUM = 12
US04 = 0
Digital Speed
Selection
Parameter
Control Inputs
I1
I2
I3
I4
S ZERO
-
0
0
0
0
S LEVELING
LS01
1
0
x
x
S HIGH SPEED
LS02
0
0
1
x
S INSPECTION
LS03
0
0
0
1
S INTERMEDIATE 1
LS05
1
1
0
x
S INTERMEDIATE 2
LS06
0
1
x
x
Symbol:
1 = Input is active
0 = Input is not active
x = Setting has no effect
When LI03 = 12, Virginia Controls has a requested High Leveling speed go to
Intermediate 2.

Table of Contents