LI03 = D(Level - High - Inspection - Correction - Intermediate 1) [Leveling at start
allowed], NUM = 16
Digital Speed
Selection
Parameter
I1
I2
I3
I4
I8**
S ZERO
-
0
0
0
0
0
S LEVELING
LS01
1
0
x
x
x
S HIGH_SPEED*
LS02
0 or 1*
1
x
x
x
S INSPECTION
LS03
0
0
1
x
x
S CORRECTION
LS04
0
0
0
1
x
S INTERMEDIATE 1
LS05
0
0
0
0
1
* Valid only at start (during deceleration, once leveling speed is reached it is not
possible to accelerate up to high speed again until after zero speed has been
selected).
** I8 is recommended because I5 and I6 are normally assigned as up and down.
However, if the up and down were redefined as I6 and I7, then I5 could be used
as the 5th speed.