US07 Date Time
This parameter will provide the current date and time in UNIX EPOCH format. (32-bit
date/time). The date and time will be used for file operations on the file system within the
Lift Drive. Additionally, the date and time will be used for logging drive status and drive
faults.
It is possible to enter a time value to this parameter via the connected keypad operator or
via serial command. The operator will support a special user interface to adjust the date
and time. Alternatively, when the value is written serially, the 32-bit integer representation
of the date will be used.
The value is backed up by the real time clock in the safety/module for a period of 40 hrs.
The date and time will be set in the production of the unit. Therefore, the default value will
be the approximate date and time the unit was produced.