EasyManua.ls Logo

Keyscan CA150 - Figure 16 - Terminate Input Wiring - RTE PIR Motion Sensor

Keyscan CA150
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Keyscan Inc. A Member of the Kaba Group CA150 Rev. B Installation Guide (07.15)
31
Figure 16 Terminate Input Wiring RTE PIR Motion Sensor
to RTE +
1K
Single end of line supervision
Normally Open
S2.8 = OFF
S2.7 = ON
3K
Non-supervised
Normally Open
S2.8 = OFF
S2.7 = OFF
Lens
NO
COM
PIR (Request To Exit)
Lens
NO
COM
Lens
NOCOM
NO = Normally Open
PIR
RTE (Request to Exit) ½ second pulse
Determines the amount of time the output relays will energize when motion is detected.
Cut View of CA150B
DOOR
RTE AUX1 AUX2
-
+
-
+
-
+
-
+
to RTE -
Double end of line supervision
Normally Open
S2.8 = ON
S2.7 = ON
to RTE +
1K
to RTE -
KI-00335E-02-14
S2.7 and S2.8 set the
supervision type universally.
The jumper setting affects
the Door Input, RTE Input,
and AUX Inputs.
S2
RDR/SUPV. CONFIG.
ON
6
7
8
9
10
2
3
4
5
1

Table of Contents

Related product manuals