EasyManuals Logo

Keyscan CA150 User Manual

Keyscan CA150
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Keyscan Inc. A Member of the Kaba Group CA150 Rev. B Installation Guide (07.15)
47
S2.7 & S2.8 - Supervision Mode DIP Switches
The CA150 supports 3 types of input supervision as listed in the table below. DIP switches S2.7 and S2.8
regulate the level of supervision universally for the door contact, the request to exit, and the
auxiliary/supervised alarm inputs on the control board. All inputs must be the same type.
Figure 24 Supervision Mode DIP Switches S2.7 & S2.8
Table 5 Supervision DIP Switch S2.7 & S2.8 Settings
S2 Switch #
Settings
Function
Notes
S2.7 & S2.8
Off=0 / On=1
Supervised Input Mode
S2.7
S2.8
0
0
Non-supervised input or digital input
1
0
Single end of line supervision
1
1
Double end of line supervision
AUX2
-
+
READER 1
READER 2
C1
(BEEP)
LED
D1
WHITE
D0
GREEN
PWR
RED
GND
BLK
C1
(BEEP)
LED
D1
WHITE
D0
GREEN
PWR
RED
GND
BLK
J6
J4
J1
RDR
RST.
CLR
MEM.
SYS.
RST.
Location of
Supervision
Mode DIP
Switches
S2.7 & S2.8
Cut view with right
cover removed.
KI-00348E-02-14
RDR/SUPV. CONFIG.SYSTEM CONFIG.
ON
6
7
8
9
10
2
3
4
5
1
6
7
8
9
10
2
3
4
5
1
11 12
ON
S1
S2
Switch Off
Off = 0
Switch On
On = 1
Switch Settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyscan CA150 and is the answer not in the manual?

Keyscan CA150 Specifications

General IconGeneral
BrandKeyscan
ModelCA150
CategoryControl Unit
LanguageEnglish