Keyscan Inc. A Member of the Kaba Group CA150 Rev. B Installation Guide (07.15)
59
Connect the Ethernet cable from the PoE power source the network switch or the injector into the
Ethernet terminal on the CA150 control board.
Within 5 seconds of establishing the connection, the CA150 should receive power from the PoE source
and begin booting up. The system status LED illuminates in amber and the on-board piezo emits a
beep.
Using a voltmeter, check the following terminals on the CA150 for +12V DC:
Reader 1 PWR RED
Reader 2 PWR RED
POWER OUT + (TB6)
DOOR output N/C or N/O (if set on POWERED)
AUX output N/C or N/O (if set on POWERED)