2 M8190A User Interface
76 M8190A User’s Guide
Source Sample Rate
The speed at which samples in the input waveform are sampled. It can be set by
typing a valid value unless the "Use As Source Sample Rate" checkbox is checked.
In this particular case, the sampling rate information contained in the input
waveform file will be always used. This field is not active if File Format is the
"SigStudioEncrypted".
The source sample rate is the sample rate, at which the input file was generated. It
can be either read from the file header (some file types) or entered manually by the
user.
Baseband Sample Rate
The speed at which samples in the output waveform will be converted. This value is
equal to the DAC sampling rate in any of the DAC direct modes and a submultiple
(x3, x12, x24, x48) for up-converter modes. It can be set in all Resampling Modes
except for the Output_RL mode. This field is not active if File Format is the
"SigStudioEncrypted".
The “baseband sample rate” is the output sample rate, the rate, to which the input
samples are resampled.
Start Sample
This field can be used to select the starting sample of the section of the input
waveform to be imported. It cannot be set to a value higher than the Stop Sample.
This field is not active if File Format is the "SigStudioEncrypted".
Stop Sample
This field can be used to select the final sample of the section of the input
waveform to be imported. It cannot be set to a value lower than the Start Sample.
This field is not active if File Format is the "SigStudioEncrypted".
Scale
This checkbox controls the way the input output waveform will be scaled after
resampling. If unchecked, the output waveform samples will not be re-scaled.
Sample levels over +1.0 or under -1.0 will be clipped. This field has no effects if File
Format is the "SigStudioEncrypted".
Scaling Section
DAC Max
Imported waveforms may occupy a limited range of the "DAC" full scale. This
parameter sets the maximum level. If set to a lower level than DAC Min, this will be
automatically set to the same level. Acceptable range for this parameter is -1/+1,
being the full dynamic range of the "instrument" DAC. This field has no effects if
File Format is the "SigStudioEncrypted".
DAC Min
DAC Max: Imported waveforms may occupy a limited range of the "DAC" full scale.
This parameter sets the minimum level. If set to a higher level than DAC Max, this
will be automatically set to the same level. Acceptable range for this parameter is -
1/+1, being the full dynamic range of the "instrument" DAC. This field has no
effects if File Format is the "SigStudioEncrypted".