EasyManua.ls Logo

Korg Triton-Rack - Page 132

Korg Triton-Rack
287 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DISK
1.1
125
Load selected
This command loads into internal memory the le or direc-
tory that was selected in the directory window (1.11b).
When you choose Load Selected from the Utility menu, a
dialog box will appear. The dialog box will differ depending
on the type of le to be loaded.
If the le to load cannot be found, or when loading a
le that was saved in parts
If the le that you need to load is not found in the current
directory or in a directory below it, a dialog box (Where is a
...) shown below will appear. This will appear in the follow-
ing cases.
If when loading a .KSC file, a .KMP file used by it
cannot be found.
If when loading a .KMP file, a .KSF file cannot be found
If when loading an AKAI S1000/S3000 format Program
file, a Sample file cannot be found.
If loading a .KSF file that was larger than the media
capacity and was therefore saved on multiple media,
when the first media has been loaded and the second
disk etc. needs to be specified.
When loading a .PCG file that was split across two or
more volumes of media, when the first volume has been
loaded and the second disk etc. is now required.
When loading a .PCG file and also simultaneously
loading a .SNG file and .KSC file, if the identically-
named .SNG/.KSC files are not found in the current
directory after loading the .PCG file.
If this dialog box appears, take the following action.
1 Select the directory that contains the le requested by
Where is a ... If the specied le is on another disk,
exchange disks and press the [SELECT], [ARP ON/OFF],
[AUDITION], [DEMO/SNG] key or any key other than a
mode key to make the TRITON-Rack detect the new disk.
Then select the appropriate directory.
It is not possible to open .PCG or .SNG les in the
Where is a ... dialog box. The [F6] (OPEN) key can-
not be used for .PCG or .SNG les.
2 Press the [F8] (Select) key to resume loading. If you
press the [F7] (Cancel) key, loading will be halted. If
you press the [F3] (Skip) key, the specied les will be
skipped, and the next le will be loaded.
Except for special cases in which the disk containing the
specied le has been damaged or is unavailable, press
the [F8] (Select) key to continue loading.
1) Load .PCG: selected icon
All data in the .PCG le will be loaded.
1 Use the Load ****** .SNG too and Load ****** .KSC
too check boxes to select the .SNG le and .KSC le.
If you check Load ******.SNG too, the file with an
identical name to the .PCG file and an extension of
.SNG will also be loaded.
If you check Load
********
.KSC too, the file with an
identical name to the .PCG file and an extension of .KSC
will also be loaded.
If this le does not exist in the current directory, load it as
described in the above procedure If the le to load can-
not be found, .
2 In .PCG Contents, specify the data to be loaded.
All: Load all data from the .PCG le.
Bank IA–IE, EA–EH: Load data of the specied bank. In this
case, use To to specify the load destination bank. When
you execute the load, the combinations, programs, drum
kits, and user arpeggio pattern data of only the specied
bank will be loaded to the load destination bank. Global set-
tings will not be loaded.
The bank of the programs used by combinations, the num-
bers of user arpeggio pattern used by combinations/pro-
grams, and the number of the drum kits used by the
Programs will be corrected automatically so that they are
appropriate.
Similarly if a .SNG le is loaded simultaneously, the bank of
the programs used by tracks of the Multi (or if there are
track/pattern events, the bank of the program within the
event) will be corrected automatically so that they are
appropriate.
If data of the specied bank is completely absent from
the .PCG le, an error of No readable data will be dis-
played, and the load operation will be halted.
If no program data of the specied bank is found in the
.PCG le, the program banks of the combination or
multi timbres/tracks will not be set automatically.
If no user arpeggio patterns of the specied bank are
found in the .PCG le, the user arpeggio pattern num-
bers of combinations, programs (/Multi) will not be set
automatically.
If no drum kits of the specied bank are found in the
.PCG le, the drum kit number of the programs will not
be set automatically.
If you specify banks I-C/I-D/I-E when loading a TRI-
TON-Rack .PCG le, drum kits and user arpeggio pat-
terns will not be loaded.
If you use All to load a .PCG le from the TRITON/
TRITONpro/TRITONproX, the following dialog box
will appear if that .PCG le contains either Drumkit
Bank C/Bank D/Bank User or User Arpeggio Pattern
Bank C/Bank D. In this dialog box you can specify the
loading destination for each bank. Only banks existing
in the .PCG le are valid. Unless you check the check
box of a valid bank, that bank will not be loaded. Press
the [F8] (OK) key to execute loading, or press the [F7]
(Cancel) key to cancel without loading.

Table of Contents

Other manuals for Korg Triton-Rack

Related product manuals