2KL/2KK
1-4-5
Fuser
section
44
Misfeed in fuser section
(third paper feeder)
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
2766 ms
45
Misfeed in fuser section
(duplex section)
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
2766 ms
Eject
section
50
Misfeed in eject section
The eject switch (ESW) does not turn off within specified
time of the registration switch (RSW) turning off.
2766 ms
The eject switch (ESW) does not turn off within specified
time of the registration clutch (RCL) turning on.
2766 ms
Feedshift
section
52
Misfeed in feedshift
section (MP tray)
The job eject switch (JBESW) does not turn on within
specified time of the feedshift switch (FSSW) turning on.
2056 ms
The feedshift switch (FSSW) does not turn on within
specified time of paper switchback operation.
1364 ms
The feedshift switch (FSSW) does not turn off within
specified time of the registration clutch (RCL) turning on.
2766 ms
The feedshift switch (FSSW) does not turn off within
specified time of the its turning on.
5907 ms
53
Misfeed in feedshift
section (cassette)
The job eject switch (JBESW) does not turn on within
specified time of the feedshift switch (FSSW) turning on.
2056 ms
The feedshift switch (FSSW) does not turn on within
specified time of paper switchback operation.
1364 ms
The feedshift switch (FSSW) does not turn off within
specified time of the registration clutch (RCL) turning on.
2766 ms
The feedshift switch (FSSW) does not turn off within
specified time of the its turning on.
5907 ms
54
Misfeed in feedshift
section (first paper
feeder)
The job eject switch (JBESW) does not turn on within
specified time of the feedshift switch (FSSW) turning on.
2056 ms
The feedshift switch (FSSW) does not turn on within
specified time of paper switchback operation.
1364 ms
The feedshift switch (FSSW) does not turn off within
specified time of the registration clutch (RCL) turning on.
2766 ms
The feedshift switch (FSSW) does not turn off within
specified time of the its turning on.
5907 ms
55
Misfeed in feedshift
section (second paper
feeder)
The job eject switch (JBESW) does not turn on within
specified time of the feedshift switch (FSSW) turning on.
2056 ms
The feedshift switch (FSSW) does not turn on within
specified time of paper switchback operation.
1364 ms
The feedshift switch (FSSW) does not turn off within
specified time of the registration clutch (RCL) turning on.
2766 ms
The feedshift switch (FSSW) does not turn off within
specified time of the its turning on.
5907 ms
Section Description Conditions Specified time