2KL/2KK
1-3-26
U073
Checking scanner operation
Description
Simulates the scanner operation under arbitrary conditions.
Purpose
To check scanner operation.
Method
1. Press the start key.
2. Select the item to be changed using the exposure adjustment keys.
3. Change the setting using the zoom +/- keys.
Paper size for each setting
4. Press the start key. The setting is set.
5. Press the interrupt key.
6. Press the start key. Scanning starts under the selected conditions.
7. To stop operation, press the stop/clear key.
Completion
Press the stop/clear key when scanning stops. The screen for selecting a maintenance item No. is displayed.
U074
Adjusting the DP input light luminosity
Description
Adjusts the luminosity of the exposure lamp for scanning originals from the DP.
Purpose
Used if the exposure amount differs significantly between when scanning an original on the platen and when
scanning an original from the DP.
Setting
1. Press the start key.
2. Change the setting using the zoom +/- keys.
Increasing the setting makes the luminosity higher, and decreasing it makes the luminosity lower.
3. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt copying mode
(which is activated by pressing the interrupt key).
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Exposure indicator Operating conditions Setting range
Exp. 1 Magnification 25 to 400%
Exp. 2 Paper size See below.
Exp. 3 On and off of the exposure lamp on or off
Setting Paper size Setting Paper size
8A4 42A5R
9 B5 47 Folio
24 11" x 8
1/2" 52 11" x 17"
36 A3 53 11" x 15"
39 B4 55 8 1/2" x 14"
40 A4R 56 8
1/2" x 11"
41 B5R 58 5
1/2" x 8 1/2"
Description Setting range Initial setting
DP input light luminosity 0 to 8 1