2KL/2KK
1-3-39
U161
Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Setting
1. Press the start key.
1. Select the item to be set using the exposure adjustment keys.
2. Change the setting using the zoom +/- keys.
Copying operation temperature 1: Temperature in copying operation at the start of copying
Copying operation temperature 2: Temperature in copying operation after the specified number of
sheets for fuser control have passed
Number of sheets for fuser control: The number of sheets to be counted for switching from copying oper-
ation temperature 1 to copying operation temperature 2
The temperatures are to be set such that Secondary stabilization >
=
Primary stabilization.
3. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U162
Stabilizing fuser forcibly
Description
Stops the stabilization fuser drive forcibly, regardless of fuser temperature.
Purpose
To forcibly stabilize the machine before the fuser section reaches stabilization temperature.
Method
1. Press the start key. "on" appears.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regard-
less of fuser temperature. The screen for selecting a maintenance item No. is Displayed.To exit the
forced stabilization mode, turn the power off and on.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Exposure
indicator
Description Setting range
Initial
setting
Exp. 1 (lit) Primary stabilization fuser temperature
120 to 185 (
°C)
145
Exp. 2 (lit) Secondary stabilization fuser temperature
120 to 185 (
°C)
165
Exp. 3 (lit) Copying operation temperature 1
160 to 220 (
°C)
175
Exp. 4 (lit) Copying operation temperature 2
160 to 220 (
°C)
185
Exp. 5 (lit) Number of sheets for fuser control 1 to 99 1
Exp. 1 (flashing) Number of sheets for fuser control (thick paper) 1 to 99 2