2KL/2KK
1-3-19
U065
Adjusting the scanner magnification
Description
Adjusts the magnification of the original scanning.
Purpose
Make the adjustment if the magnification in the main scanning direction is incorrect.
Make the adjustment if the magnification in the auxiliary scanning direction is incorrect.
Caution
Adjust the magnification of the scanner in the following order.
Method
1. Press the start key.
2. Select the item using the exposure adjustment keys.
Adjustment: main scanning direction
1. Light exp. 1 using the exposure adjustment key.
2. Press the interrupt key.
3. Place an original and press the start key to make a test copy.
4. Change the setting value using the zoom +/- keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Figure 1-3-7
5. Press the start key. The value is set.
Adjustment: auxiliary scanning direction
1. Light exp. 2 using the exposure adjustment key.
2. Press the interrupt key.
3. Place an original and press the start key to make a test copy.
4. Change the setting value using the zoom +/- keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Figure 1-3-8
5. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
U065
(main scanning
direction)
U053
(P.1-3-17)
U067
(P.1-3-21)
U065
(auxiliary scanning
direction)
U070
(P.1-3-23)
Exposure
indicator
Description Setting
range
Initial
setting
Exp. 1 Scanner magnification in the main scanning direction -25 to 25 0
Exp. 2 Scanner magnification in the auxiliary scanning direction -25 to 25 -10
Original Copy
example
Copy
example 2
Original Copy
example 1
Copy
example 2