2MV
1-3-154
U641 Setting communication time 2
Description
Sets the time-out time for fax transmission.
Purpose
To improve transmission performance for international communications mainly.
Method
1. Press the start key.
2. Select the item to be set.
Setting:[T0 Time Out]
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Depending on the quality of the exchange, or when the auto select function is selected at the
destination unit, a line can be disconnected. Change the setting to prevent this problem.
1. Change the setting using the +/- keys or numeric keys.
2. Press the start key. The value is set.
Setting:[T1 Time Out]
Sets the time before receiving the correct signal after call reception. No change is necessary for
this maintenance item.
1. Change the setting using the +/- keys or numeric keys.
2. Press the start key. The value is set.
Item No. Description
Display Description
T0 Time Out Sets the T0 time-out time.
T1 Time Out Sets the T1 time-out time.
T2 Time Out Sets the T2 time-out time.
Ta Time Out Sets the Ta time-out time.
Tb1 Time Out Sets the Tb1 time-out time.
Tb2 Time Out Sets the Tb2 time-out time.
Tc Time Out Sets the Tc time-out time.
Td Time Out Sets the Td time-out time.
Description Setting range Initial setting
T0 time-out time 30 to 90 s 56
Description Setting range Initial setting
T1 time-out time 30 to 90 s 36