EasyManua.ls Logo

Kyocera TASKalfa 2550ci - Page 273

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV
1-4-17
2211 Drum motor K startup error
Drum motor K is not stabilized
within 3 s since the motor is
activated.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum motor K and engine PWB (YC3)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor. Replace the Drum motor K.
Defective PWB. Replace the engine PWB and check for cor-
rect operation (see page 1-5-45).
2212 Drum motor YCM startup
error
Drum motor YCM is not stabi-
lized within 3 s since the
motor is activated.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum motor YCM and engine PWB (YC3)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor. Replace the Drum motor YCM.
Defective PWB. Replace the engine PWB and check for cor-
rect operation (see page 1-5-45).
2300
Fuser motor steady-state
error
The rated speed signal
detected the stability OFF
continuously for 1 s after the
fuser motor stabilizes.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser motor and engine PWB (YC4)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor. Replace the Fuser motor.
Defective PWB. Replace the engine PWB and check for cor-
rect operation (see page 1-5-45).
2310 Fuser motor startup error
Fuser motor is not stabilized
within 3 s since the motor is
activated.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser motor and engine PWB (YC4)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor. Replace the fuser motor.
Defective PWB. Replace the engine PWB and check for cor-
rect operation (see page 1-5-45).
Code Contents Causes
Check procedures/
corrective measures

Table of Contents

Other manuals for Kyocera TASKalfa 2550ci

Related product manuals