2MV-1
1-4-23
4101 BD initialization problem (K)
BD is not detected within two
seconds after the polygon
motor stabilizes.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
BDPWB and APCPWB
APCPWB and LSU connect PWB (YC1)
LSU connect PWB and engine PWB (YC12)
Defective
APCPWB.
Replace the Laser scanner unit (K).
(see page 1-5-21)
Defective BDPWB.
Defective PWB. Replace the engine PWB or LSU connect
PWB and check for correct operation
(see page 1-5-45).
4102 BD initialization problem (C)
BD is not detected within two
seconds after the polygon
motor stabilizes.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
BDPWB and APCPWB
APCPWB and LSU connect PWB (YC3)
LSU connect PWB and engine PWB (YC12)
Defective
APCPWB.
Replace the Laser scanner unit (C).
(see page 1-5-21)
Defective BDPWB.
Defective PWB. Replace the engine PWB or LSU connect
PWB and check for correct operation
(see page 1-5-45).
4103 BD initialization problem
(M)
BD is not detected within two
seconds after the polygon
motor stabilizes.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
BDPWB and APCPWB
APCPWB and LSU connect PWB (YC2)
LSU connect PWB and engine PWB (YC12)
Defective
APCPWB.
Replace the Laser scanner unit (M).
(see page 1-5-21)
Defective BDPWB.
Defective PWB. Replace the engine PWB or LSU connect
PWB and check for correct operation
(see page 1-5-45).
Code Contents Causes
Check procedures/
corrective measures