EasyManua.ls Logo

Kyocera TASKalfa 2550ci - Page 287

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV-8
1-4-31
6990 Fuser unit type mismatch
problem
Absence of the fuser unit is
detected.
Defective PWB. Replace the IH PWB and check for correct
operation (see page 1-5-53).
7101
Toner sensor K error
The sensor outputs are for 5
seconds, 23 or less, or 248
or more.
Defective Devel-
oper unit.
Replace the developer unit K
(see page 1-5-14).
Defective PWB. Replace the engine PWB check for correct
operation (see page 1-5-45).
7102
Toner sensor C error
The sensor outputs are for 5
seconds, 23 or less, or 248
or more.
Defective Devel-
oper unit.
Replace the developer unit C
(see page 1-5-14).
Defective PWB. Replace the engine PWB check for correct
operation (see page 1-5-45).
7103
Toner sensor M error
The sensor outputs are for 5
seconds, 23 or less, or 248
or more.
Defective Devel-
oper unit.
Replace the developer unit M
(see page 1-5-14).
Defective PWB. Replace the engine PWB check for correct
operation (see page 1-5-45).
7104
Toner sensor Y error
The sensor outputs are for 5
seconds, 23 or less, or 248
or more.
Defective Devel-
oper unit.
Replace the developer unit Y
(see page 1-5-14).
Defective PWB. Replace the engine PWB check for correct
operation (see page 1-5-45).
7401 Developer unit K type mis-
match error
Absence of the developer unit
K is detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Developer unit K and drum connect PWB
(YC9)
Drum connect PWB and engine PWB (YC4)
Different type of
the developer unit
is installed.
Install the correct developer unit
(see page 1-5-14).
Code Contents Causes
Check procedures/
corrective measures

Table of Contents

Other manuals for Kyocera TASKalfa 2550ci

Related product manuals