EasyManua.ls Logo

Kyocera TASKalfa 2550ci - Page 293

Kyocera TASKalfa 2550ci
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MV
1-4-37
8030 Tray upper limit detection
problem (document fin-
isher)
When the tray elevation motor
raises a tray, the ON status of
the tray upper limit sensor is
detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Tray upper limit sensor and DF main PWB
(CN5)
Paper surface sensor 1/2 and DF main PWB
(CN6)
Defective tray
upper limit sensor,
paper surface sen-
sor 1/2.
Replace the sensor.
Defective PWB. Replace the DF main PWB and check for
correct operation.
8040 Belt problem (document fin-
isher)
The belt sensor does not turn
on/off within specified time of
the belt solenoid turning on.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Belt sensor and DF main PWB (CN10)
Belt solenoid and DF main PWB (CN21)
Defective belt sen-
sor.
Replace the belt sensor.
Defective belt sole-
noid.
Replace the belt solenoid.
Defective PWB. Replace the DF main PWB and check for
correct operation.
8140 Tray elevation motor prob-
lem (document finisher)
The tray low limit sensor or
paper surface sensor 1/2 can-
not be detected to be on
within 10 s since the tray ele-
vation motor is activated.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Tray elevation motor and DF main PWB
(CN15)
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Tray lower limit sensor, and DF main PWB
(CN5)
Paper surface sensor 1/2 and DF main PWB
(CN6)
The tray elevation
motor malfunc-
tions.
Replace the tray elevation motor.
Defective tray
lower limit sensor,
paper surface sen-
sor 1/2.
Replace the sensor.
Defective PWB. Replace the DF main PWB and check for
correct operation.
Code Contents Causes
Check procedures/
corrective measures

Table of Contents

Other manuals for Kyocera TASKalfa 2550ci