Loading...
2MV
2-3-35
YC9
34 GND - - Ground
Connected to
CCD PWB
35 CCDSEL I
0/3.3 V DC Select signal
36 GND -
- Ground
37 AFE_MCLK O
0/3.3 V DC (pulse) Clock signal
38 GND(AFE_SH
D)
-
- Ground
39 CLPIN O
0/3.3 V DC Clamp signal
40 GND(AFE_SH
P)
-
- Ground
41 GND -
- Ground
YC11
15.1V5 O
5 V DC 5 V DC power output to CCDPWB
Connected to
CCD PWB
2GND -
- Ground
310V5 O
DC10V 10 V DC power output to CCDPWB
4GND -
- Ground
53.3V5 O
3.3 V DC 3.3 V DC power output to CCDPWB
6GND -
- Ground
YC12
1GND(SPARE) -
- Ground
Connected to
DP main
PWB
2DP_TMG I
0/3.3 V DC DPTS: On/Off
3 DP_RDY I
0/3.3 V DC Ready signal
4 DP_SEL O
0/3.3 V DC Select signal
5DP_CLK O
0/3.3 V DC (pulse) Clock signal
6 DP_SO O
0/3.3 V DC (pulse) Serial communication data signal
7 DP_SI I
0/3.3 V DC (pulse) Serial communication data signal
8DP_OPEN I
0/3.3 V DC DPOCSW: On/Off
9NC -
- Not used
10 GND -
- Ground
11 GND -
- Ground
12 GND -
- Ground
13 NC -
- Not used
14 24V4 O
24 V DC 24 V DC power output to DPMPWB
15 24V4 O
24 V DC 24 V DC power output to DPMPWB
16 24V4 O
24 V DC 24 V DC power to DPMPWB
YC13
1GND -
- Ground
Connected to
original size
sensor
2ORG_SW I
0/3.3 V DC OSS: On/Off
35.1V5 O
5 V DC 5 V DC power output to OSS
Connector Pin Signal I/O Voltage Description