TITAN VERSA LEAK DETECTORS
OPERATIONS AND MAINTENANCE MANUAL

Table of Contents

Questions and Answers

  • L
    lisalongAug 21, 2025
    What to do if the ambient temperature is too high for LACO Technologies Security Sensors?
    • T
      timothydavidAug 21, 2025
      If the ambient temperature is too high for your LACO Technologies Security Sensors, ensure the leak detector is used within the required temperature tolerance.
  • M
    Miss Cindy Fleming DVMSep 3, 2025
    What to do if the primary pump switch is OFF on LACO Technologies Security Sensors?
    • W
      William BoydSep 3, 2025
      If your LACO Technologies Security Sensors show 'Primary pump switch OFF', place the switch to the ON position.
  • R
    Rebecca BerrySep 1, 2025
    What to do if the ambient temperature is too low for LACO Technologies Security Sensors?
    • D
      David GregorySep 1, 2025
      If the ambient temperature is too low for your LACO Technologies Security Sensors, ensure the leak detector is used within the required temperature tolerance.
  • J
    John FowlerAug 30, 2025
    What to do if leak rate is measured but background is too high to validate the calibration on LACO Technologies Security Sensors?
    • K
      Kaitlyn DrakeAug 31, 2025
      If your LACO Technologies Security Sensors leak rate is measured but the background is too high to validate the calibration, perform a calibration with an external leak and check the calibrated leak parameters.
  • L
    Laura QuinnAug 29, 2025
    What to do if background is too high for calibration in LACO Technologies Security Sensors?
    • P
      Peter StrongAug 29, 2025
      If the background is higher than 20% of the calibrated leak value of reference for the calibration in your LACO Technologies Security Sensors, degas the analyzer cell by pumping in the cell for 10 minutes, and then launch a calibration.
  • C
    codyleeAug 27, 2025
    What to do if the measured leak value is too high on LACO Technologies Security Sensors?
    • E
      Elizabeth WoodsAug 27, 2025
      If your LACO Technologies Security Sensors have a measured leak value that is too high, check the calibrated leak parameters.
  • R
    Ryan BrownAug 27, 2025
    How to troubleshoot lack of sensitivity in LACO Technologies Security Sensors?
    • V
      Victoria RodriguezAug 27, 2025
      If your LACO Technologies Security Sensors show a lack of sensitivity, first, place the switch to the ON position. Second, check the calibrated leak parameters.
  • M
    Mrs. Robin MasseyAug 25, 2025
    What to do if ambient temperature is too high and fan is defective in LACO Technologies Security Sensors?
    • D
      Donna RosarioAug 25, 2025
      If the ambient temperature is too high and the fan is defective in your LACO Technologies Security Sensors, ensure the leak detector is used in the required temperature tolerance and replace the fan.
  • B
    Brent MartinezAug 23, 2025
    What to do if ambient temperature is too high and pump fan is obstructed in LACO Technologies Security Sensors?
    • S
      Shelley GouldAug 23, 2025
      If the ambient temperature is too high and the pump fan is obstructed in your LACO Technologies Security Sensors, allow the pump to cool down, check the room temperature, and clean the fan.

Summary

About This Manual

Target Groups

Identifies the intended audience for this operating manual.

Reference Documents

Lists all applicable documents referenced within the manual.

Displaying Information

Explains how warning messages are presented and their severity.

Safety

Intended Use

Defines the proper applications and limitations for the leak detector.

Unintended Use

Details prohibited uses that may void warranties and cause damage.

Owner Requirements

Outlines responsibilities for operating and maintaining the equipment.

Operator Requirements

Specifies qualifications and duties for personnel operating the device.

Dangers

Highlights significant hazards related to electrical and chemical substances.

Transport and Storage

Transport

Provides instructions and precautions for safely moving the leak detector.

Storage

Specifies the recommended environmental conditions for storing the device.

Description

Function

Explains the core capabilities and leak testing methods of the detector.

Scope of Delivery

Lists the main components included with the leak detector assembly.

Configurations

Details the different physical models and their specifications.

Technical Data

Presents detailed specifications and performance parameters for all models.

Installation

Mechanical Setup and Mounting

Guides on proper placement and environmental considerations for installation.

Mechanical Connections

Details how to connect various ports and accessories to the detector.

Electrical Power Connection

Instructions for safely connecting the device to an electrical power source.

Electrical Interfaces

Overview of available ports and their functions for connectivity.

Operation

Prerequisites for Use

Checks and conditions required before powering on the leak detector.

Power-On Process

Step-by-step guide for starting up the TITAN VERSA leak detector.

Power-Off Process

Procedure for safely shutting down the TITAN VERSA leak detector.

General Use Guidelines

Covers essential operational principles and methods for leak testing.

Calibration

Instructions for calibrating the leak detector for accurate measurements.

Vacuum Method Leak Testing

Explains methods for performing leak tests using vacuum techniques.

Sniff Method Leak Testing

Details on how to perform leak detection using the sniff method.

User Interface Features

Description of the touchscreen display, buttons, and navigation elements.

Test Settings

Configuration options for various test parameters and modes.

Calibration Settings

Menu for configuring calibrated leak standards and starting calibration.

System Settings

Configuration options for mass spec, units, communication, and display.

Maintenance Settings

Access to maintenance schedules, counters, and system information.

Advanced Settings

Access to advanced parameters for qualified technicians, use with caution.

Factory Default Settings

Table of default parameter values and corresponding serial commands.

Troubleshooting

Warning and Error Messages

Guide to identifying and resolving common warnings and fault conditions.

Maintenance and Service

Maintenance Cautions and Requirements

Critical safety precautions and requirements before performing maintenance.

Protective Equipment

Lists essential personal protective equipment (PPE) for maintenance tasks.

Maintenance Tools and Parts

Lists tools and parts included in the maintenance kit and their uses.

Maintenance Tasks and Intervals

Schedule of recommended maintenance tasks and their required intervals.

Removing Covers

Procedures for removing the front and back covers for access.

Fuses

Details on fuse types, locations, and replacement procedures.

Calibrated Leak Maintenance

Procedures for recalibrating and replacing the calibrated leak standard.

Turbo Pump

Information and procedures for maintaining the turbo pump, including oil wick replacement.

VERSA T Wet Pump Maintenance

Maintenance procedures specific to the VERSA T wet pump.

VERSA T Dry Pump Maintenance

Maintenance procedures specific to the VERSA T dry pump.

Accessories

TITAN VERSA Accessories

List of available accessories for the TITAN VERSA leak detector.

APPENDIX

Reference Information

Contains supplementary data including conversions and flow regimes.

Leak Rate Conversions

Table for converting between different leak rate units.

Pressure Conversions

Table for converting between various pressure units.

LACO Technologies TITAN VERSA C Specifications

General IconGeneral
BrandLACO Technologies
ModelTITAN VERSA C
CategorySecurity Sensors