If regeneration is needed, but the current conditions do
not allow the engine to perform regeneration automati-
cally, the following warning message will appear (Figure
4-32):
Figure 4-32. Regen Alert Message Pop-Up Screen
When safe to do so, raise the engine speed
above 2000 RPMs to allow automatic
regeneration. The High Exhaust icon will
appear in the alerts window when regen
begins.
NOTE: If action is not taken for the automatic
regeneration to occur, the soot level
(indicated by the DPF level shown on the
main screen) will continue to rise. If the DPF
level reaches Level 3, the operator must
perform the parked regeneration process
described on Pages 4-21 to 4-23.
Disable/Enable RegenDisable/Enable Regen
If conditions are unsafe for the engine to perform a
regeneration automatically, the operator may choose to
temporarily inhibit (disable) the regeneration process.
Press the Main Menu button, then navigate to DPF Com-
mands and press the () button to select. (Figure 4-18
on Page 4-12) “Disable Auto Regen” now appears in
the soft key banner (button #5). (Figure 4-31)
Figure 4-33. Disable (Inhibit) Regen Screen
NOTE: The ability to inhibit (disable) regeneration
is only possible at DPF Levels 1 and 2. (See
DPF Levels, Pages 4-18 to 4-20)