Step21.Restarttheserver.Thesystembeginsthepower-onself-test(POST).
Step22.Iftheserecoveryeffortsfail,contactyourIBMservicerepresentativeforsupport.
In-bandautomatedbootrecoverymethod
Thissectiondetailsthein-bandautomatedbootrecoverymethod.
Note:UsethismethodiftheSystemboardLEDonthelightpathdiagnosticspanelislitandthereisalog
entryorBootingBackupImageisdisplayedonthefirmwaresplashscreen;otherwise,usethein-band
manualrecoverymethod.
Step1.Boottheservertoanoperatingsystemthatissupportedbythefirmwareupdatepackagethat
youdownloaded.
Step2.Performthefirmwareupdatebyfollowingtheinstructionsthatareinthefirmwareupdatepackage
readmefile.
Step3.Restarttheserver.
Step4.Atthefirmwaresplashscreen,pressF3whenpromptedtorestoretotheprimarybank.The
serverbootsfromtheprimarybank.
Out-of-bandmethod
SeetheIMM2documentation(IntegratedManagementModuleIIUser'sGuide)at
http://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.lenovo.sysx.imm2.doc/
printable_doc.html.
Automatedbootrecovery(ABR)
UsethisinformationforAutomatedbootrecovery(ABR).
Whiletheserverisstarting,iftheintegratedmanagementmoduleIIdetectsproblemswiththeserver
firmwareintheprimarybank,theserverautomaticallyswitchestothebackupfirmwarebankandgives
youtheopportunitytorecoverthefirmwareintheprimarybank.ForinstructionsforrecoveringtheUEFI
firmware,see“Recoveringtheserverfirmware(UEFIupdatefailure)”onpage118
.Afteryouhaverecovered
thefirmwareintheprimarybank,completethefollowingsteps:
Step1.Restarttheserver.
Step2.WhenthepromptPressF3torestoretoprimaryisdisplayed,pressF3tostarttheserverfrom
theprimarybank.
Nx-bootfailure
UsethisinformationforNx-bootfailure.
Configurationchanges,suchasaddeddevicesoradapterfirmwareupdates,andfirmwareorapplication
codeproblemscancausetheservertofailPOST(thepower-onself-test).Ifthisoccurs,theserverresponds
ineitherofthefollowingways:
TheserverrestartsautomaticallyandattemptsPOSTagain.
Theserverhangs,andyoumustmanuallyrestarttheserverfortheservertoattemptPOSTagain.
Afteraspecifiednumberofconsecutiveattempts(automaticormanual),theNx-bootfailurefeaturecauses
theservertoreverttothedefaultUEFIconfigurationandstarttheSetuputilitysothatyoucanmakethe