Hazardousvoltage,current,andenergylevelsarepresentinsideanycomponentthathasthislabel
attached.Therearenoserviceablepartsinsidethesecomponents.Ifyoususpectaproblemwith
oneoftheseparts,contactaservicetechnician.
Readthesafetyinformationin“Safety”onpagev
and“Installationguidelines”onpage33.
Toreplaceorinstallahot-swappowersupply,completethefollowingsteps.
Step1.Graspthesideclipandpulltoremovethepower-supplyfillerpanelfromtheemptypower-supply
bay.Savethepower-supplyfillerpanelincaseyouremovethepowersupplyatalatertime.
Important:Duringnormaloperation,eachpower-supplybaymustcontaineitherapowersupply
orpower-supplyfillerpanelforpropercooling.
000000000
000000000
000000000
000000000
Power
supply
filler
Power
supply
Power
supply
release tab
Figure50.Hot-swappowersupplyinstallation
Step2.Slidethehot-swappowersupplyintothebayuntilthereleaselatchclicksintoplace.
Step3.Connectoneendofthepowercordforthenewpowersupplyintotheacconnectorontheback
ofthepowersupply;then,connecttheotherendofthepowercordintoaproperlygrounded
electricaloutlet.
Step4.Iftheserveristurnedoff,turnontheserver.
Step5.MakesurethattheacpowerLEDonthepowersupplyislit,indicatingthatthepowersupplyis
operatingcorrectly.Iftheserveristurnedon,makesurethatthedcpowerLEDonthepower
supplyislitalso.
Ifyouhavereplacedaservercomponentorinstalledanoptionaldeviceintheserver,youneedtoreconnect
thepowercordsandallexternalcables,andturnontheserverandperipheraldevices.
RemovingandreplacingTier2CRUs
ThissectionprovidesinformationforremovingandreplacingTier2CRUsintheserver.
YoumayinstallaTier2CRUyourselforrequestIBMtoinstallit,atnoadditionalcharge,underthetypeof
warrantyservicethatisdesignatedforyourserver.
168LenovoSystemx3250M4InstallationandServiceGuide