Riser-card
assembly
Expansion slot 1
Expansion slot 2
Adapter
Adapter
Expansion-slot cover
Expansion-slot cover
Figure42.Adapterremoval
Ifyouareinstructedtoreturntheservercomponentoroptionaldevice,followallpackaginginstructions,
anduseanypackagingmaterialsforshippingthataresuppliedtoyou.
ReplacingaServeRAIDadapter
UsethisinformationtoreplaceanIBMServeRAIDadapter.
Forconfigurationinformation,seetheServeRAIDdocumentationathttp://www.lenovo.com/support.
Important:ToensurethatanyofyourServeRAIDadaptersfunctionproperlyonUEFI-basedservers,make
surethattheadapterfirmwareandsupportingdevicedriversareupdatedtoatleast11.x.x-XXX.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage33.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
ToreplaceanIBMServeRAIDadapter,completethefollowingsteps.
Note:Ifpossible,backuporrecordyourRAIDconfigurationinformationbeforereplacingtheadapter.See
thedocumentationforyourRAIDadapterforinformationandinstructions.DocumentationforServeRAID
adapterscanbedownloadedfromhttp://www.lenovo.com/support.
Step1.Removethecover(see“Removingthecover”onpage131).
Step2.RemovethePCIriser-cardassembly(see“RemovingthePCIriser-cardassembly”onpage136).
Step3.Removetheexpansion-slotcoverontheslotthatyouintendtouseandsaveforfutureuse.
Attention:PCIexpansion-slotcoversmustbeinstalledonallvacantslots.Thismaintainsthe
electronicemissionsstandardsoftheserverandensuresproperventilationofservercomponents.
Chapter6.Removingandreplacingcomponents143