ProvidestheprefixofthemessageIDandthesequencenumberthatisusedbytheCIMmessage
registry.
SNMPTrapID
TheSNMPtrapIDthatisfoundintheSNMPalertmanagementinformationbase(MIB).
AutomaticallycontactService
IfthisfieldissettoYes,andyouhaveenabledElectronicServiceAgent(ESA),IBMSupportwillbe
notifiedautomaticallyiftheeventisgenerated.
WhileyouwaitforIBMSupporttocall,youcanperformtherecommendedactionsfortheevent.
Userresponse
Indicateswhatactionsyoushouldperformtosolvetheevent.
Performthestepslistedinthissectionintheordershownuntiltheproblemissolved.Afteryouperform
alloftheactionsthataredescribedinthisfield,ifyoucannotsolvetheproblem,contactIBMSupport.
Note:Thislistincludeserrorcodesandmessagesthatmightnotapplytothismachinetypeandmodel.
ThefollowingisthelistofIMM2errormessagesandsuggestedactionstocorrectthedetectedserver
problems.FormoreinformationaboutIMM2,seetheIntegratedManagementModuleIIUser'sGuide
athttp://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.lenovo.sysx.imm2.doc/
printable_doc.html.
IMMEventsthatautomaticallynotifySupport
YoucanconfiguretheIBMFlexSystemManagerortheCMMtoautomaticallynotifySupport(alsoknownas
callhome)ifcertaintypesoferrorsareencountered.Ifyouhaveconfiguredthisfunction,seethetablefor
alistofeventsthatautomaticallynotifySupport.
Table35.EventsthatautomaticallynotifySupport
EventIDMessageString
Automatically
NotifySupport
40000086-00000000
TestCallHomeGeneratedbyuser[arg1].
Yes
40000087-00000000
ManualCallHomebyuser[arg1]:[arg2].
Yes
80010202-0701ffff
Numericsensor[NumericSensorElementName]goinglow
(lowercritical)hasasserted.(CMOSBattery)
Yes
80010902-0701ffff
Numericsensor[NumericSensorElementName]going
high(uppercritical)hasasserted.
Yes
806f0021-2582ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(AllPCIError)
Yes
806f0021-3001ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(PCI1)
Yes
806f0108-0a01ffff
[PowerSupplyElementName]hasFailed.(PowerSupply1)
Yes
806f0108-0a02ffff
[PowerSupplyElementName]hasFailed.(PowerSupply2)
Yes
806f010c-2001ffffUncorrectableerrordetectedfor
[PhysicalMemoryElementName]onSubsystem
[MemoryElementName].(DIMM1)
Yes
806f010c-2002ffffUncorrectableerrordetectedfor
[PhysicalMemoryElementName]onSubsystem
[MemoryElementName].(DIMM2)
Yes
204LenovoSystemx3250M4InstallationandServiceGuide