2.Securethecableonthesystemboardwithcabletieafterrouting.
ServeRAID adapter
SAS/SATA signal
cable
Hard disk
drive backplane
Step5.AligntheServeRAIDadaptersothatthekeysaligncorrectlywiththeconnectoronthePCI
riser-cardassembly.
Step6.InserttheServeRAIDadapterintotheconnectoronthePCIriser-cardassemblyuntilitisfirmly
seated.
Attention:Incompleteinsertionmightcausedamagetotheserverortheadapter.
Step7.InstallthePCIriser-cardassembly(see“ReplacingthePCIriser-cardassembly”onpage55).
Ifyouhaveotherdevicestoinstall,dosonow.Otherwise,goto“Completingtheinstallation”onpage54.
Note:Whenyourestarttheserver,youarepromptedtoimporttheexistingRAIDconfigurationtothe
newServeRAIDadapter.
Installingahot-swappowersupply
Usethisinformationtoinstallahot-swappowersupply.
Thefollowingnotesdescribethetypeofpowersupplythattheserversupportsandotherinformationthat
youmustconsiderwhenyouinstallapowersupply:
•Dependingonyourservermodel,theservercomesstandardwithone460-watthot-swappowersupply.
Forredundancysupport,youmustinstallanadditionalhot-swappowersupply,ifoneisnotinstalledin
yourmodel.
•Makesurethatthedevicesthatyouareinstallingaresupported.Foralistofsupportedoptionaldevices
fortheserver,seehttp://www.lenovo.com/serverproven/.
Statement5
52LenovoSystemx3250M4InstallationandServiceGuide