No
Automaticallynotifysupport
No
AlertCategory
System-Other
SNMPTrapID
CIMInformation
Prefix:PLATID:0179
UserResponse
Noaction;informationonly.
•816f0807-0301ffff:[ProcessorElementName]hasbeenEnabled.(CPU1)
ThismessageisfortheusecasewhenanimplementationhasdetectedaProcessorhasbeenEnabled.
Mayalsobeshownas816f08070301ffffor0x816f08070301ffff
Severity
Info
Serviceable
No
Automaticallynotifysupport
No
AlertCategory
System-Other
SNMPTrapID
CIMInformation
Prefix:PLATID:0060
UserResponse
Noaction;informationonly.
•816f0813-0301ffff:System[ComputerSystemElementName]hasrecoveredfromanUncorrectable
BusError.(CPUs)
Thismessageisfortheusecasewhenanimplementationhasdetectedathatasystemhasrecovered
fromaBusUncorrectableError.
Mayalsobeshownas816f08130301ffffor0x816f08130301ffff
Severity
Info
Serviceable
No
AppendixA.IntegratedManagementModuleII(IMM2)errormessages401