UserResponse
Completethefollowingsteps:
1.Ifsystemfailedtobootsuccessfully,DCcyclesystem.
2.IfsystembootstoF1steup,flashUEFIimageandresetbanktoprimary(ifrequired).Ifsystem
bootswithouterror,recoveryiscompleteandnoadditionalactionisrequired.
3.Ifsystemfailstoboot,orifflashattemptfails,(Trainedservicetechnicianonly)Replacethe
systemboard.
S.51003[S.51003]AnuncorrectablememoryerrorwasdetectedinDIMMslot%onrank%.
Explanation:[S.51003]Anuncorrectablememoryerrorwasdetectedonprocessor%channel%.The
failingDIMMwithinthechannelcouldnotbedetermined.[S.51003]Anuncorrectablememoryerrorhas
beendetectedduringPOST.FatalMemoryErrorOccurred
Severity
Error
UserResponse
Completethefollowingsteps:
1.Ifthenodehasrecentlybeeninstalled,moved,serviced,orupgraded,verifythattheDIMM
isproperlyseatedandvisuallyverifythatthereisnoforeignmaterialinanyDIMMconnector
onthatmemorychannel.Ifeitheroftheseconditionsisfound,correctandretrywiththesame
DIMM.(Note:EventLogmaycontainarecent00580A4eventdenotingdetectedchangein
DIMMpopulationthatcouldberelatedtothisproblem.)
2.IfnoproblemisobservedontheDIMMconnectorsortheproblempersists,replacetheDIMM
identifiedbyLightPathand/oreventlogentry.
3.Ifproblemre-occursonthesameDIMMconnector,replacetheotherDIMMsonthesame
memorychannel.
4.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliestothis
memoryerror.
5.(TrainedServicetechnicianonly)Ifproblemre-occursonthesameDIMMconnector,inspect
connectorfordamage.Iffound,replacesystemboard.
6.(TrainedServicetechnicianonly)ReplaceaffectedProcessor.
7.(TrainedServicetechnicianonly)Replacesystemboard.
S.51006[S.51006]Amemorymismatchhasbeendetected.Pleaseverifythatthememory
configurationisvalid.
Explanation:OneorMoreMismatchedDIMMsDetected
Severity
Error
UserResponse
Completethefollowingsteps:
1.Couldfollowanuncorrectablememoryerrororfailedmemorytest.Checklogandservicethat
eventfirst.DIMMsdisabledbyothererrorsoractionscouldcausethisevent.
2.VerifythattheDIMMsareinstalledinthecorrectpopulationsequence,accordingtotheservice
informationforthisproduct.
416LenovoSystemx3250M4InstallationandServiceGuide