–Expansionslot1:Low-profilewith2Ubracket(thisslotisdedicatedforServeRAID-10ilv2SAS/SATA
controller)
–Expansionslot2:Full-height,half-length
Slot 2 PCIe Gen2 x8 (8, 4, 1)
Slot 1 PCIe Gen2 x8 (4, 1)
Figure19.PCIriser-cardassembly
•TheoptionalServeRAID-BR10ilv2controllermustbeinstalledinexpansionslot1onthePCIriser-card
assembly.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage33.
Ifyouareinstallinganoptionaldeviceintheserver,turnofftheserverandperipheraldevices,anddisconnect
thepowercordsandallexternalcables.
Toinstallanadapter,completethefollowingsteps.
Step1.RemovethePCIriser-cardassembly(see“RemovingthePCIriser-cardassembly”onpage37).
Step2.Touchthestatic-protectivepackagethatcontainstheadaptertoanyunpaintedmetalsurfaceon
theserver;then,removetheadapterfromthepackage.
Step3.Placetheadapter,componentsideup,onaflat,static-protectivesurfaceandsetanyjumpersor
switchesasdescribedbytheadaptermanufacturer,ifnecessary.
Step4.Followthecablinginstructions,ifanycomewiththeadapter.Routetheadaptercablesbefore
youinstalltheadapter.
Step5.Removetheexpansion-slotcoverfromthePCIriser-cardassemblyandsaveforfutureuse.
Step6.AligntheconnectorontheadapterwiththeconnectoronthePCIriser-cardassembly,then,insert
theadapterintothePCIriser-cardassembly.PresstheedgeoftheconnectorfirmlyintothePCI
riser-cardassembly.MakesurethattheadapterissecurelyinstalledinthePCIriser-cardassembly.
Important:MakesurethattheU-shapedopeninginthemetaladapterbracketengagesthe
tabontheexpansion-slotbracket.
Chapter2.Installingoptionaldevices49