7. WEB Control Application
7-10
③ Tension Reference Input Setting by Communication (In case of using loadcell)
To conduct tension reference input setting by communication, you may use communication common area
Address 0x0511. For further detail, please refer to communication common area data.
④ Dancer Position Input Setting by Keypad (In case of using dancer)
To conduct dancer position input setting by Keypad, you may set WEB_28 PIDRef Sel to “Dancer Pos” and
then set WEB_29 Dancer Pos.
⑤ Dancer position input Setting by analog input (In case of using dancer)
To conduct dancer position input setting by analog input, you may set WEB_29 PIDRef Sel to “Dancer Pos”,
and then set one of Analog input AIO_01 Ai1 Define, AIO_13 Ai2 Define, and AIO_25 Ai3 Define to “Dancer
Ref”.
⑥ Dancer position input Setting by communication (In case of using dancer)
To conduct dancer position input setting by communication, you may set WEB_28 PIDRef Sel to “Dancer
Pos” and then use communication common area address 0x0512.. For further detail, please refer to
communication common area data.
All the functions related with PID control should be set. The relevant function codes are as
follows;
-. WEB_30 ProcPID Kp1
-. WEB_32 ProcPID Ki1
-. WEB_42 PIDOGainRe or WEB_43 PIDOGainUn
-. Please operate it with the rest function codes related with PID control set to default. If any
change required, please refer to the explanation on WEB group function.
EB▶ PIDRef Sel
28 Dancer Pos
EB▶ Dancer Pos
29 50.0 %
IO▶ Ai1 Define
01 Dancer Ref
EB▶ PIDRef Sel
28 Dancer Pos
EB▶ PIDRef Sel
28 Dancer Pos