7. WEB Control Application
7-19
function input terminal, by analog input terminal , and by communication.
Function
Code
Loader Display Name of Function Set Range Unit
Factory
Default
WEB_03 DiaPresetSrc
Diameter Initialization Type
Setting
Keypad
Analog
Option
Keypad
① Initialization of Core by Multi-function Input Terminal
-. Initialization of Core by Multi-function Input Terminal requires setting WEB_03 to “Keypad” first.
-. Select one of multi-function input terminals (DIO_01 ~ DIO_07), and set it to “Dia Preset”.
-. Select two of multi-function input terminals (DIO_01 ~ DIO_07), and set them to “CoreSize-L” and
“CoreSize-H”.
-. Core can be initialized according to On/Off of multi-function input terminal set to “Dia Preset”. The core value
initialized becomes, however, one of the initial values set in WEB_04 ~ WEB_07 according to On/Off of the
multi-function input terminal set to “CoreSize-L” and “CoreSize-H”.
-. In case of using the core in one kind only, you don’t need to set “CoreSize-L” and “CoreSize-H”. In this case,
only WEB_04 Diam Preset 1 is applied to the core.
Example) The initial diameter value when DIO_01, DIO_02, and DIO_03 are set to “Dia Preset”, “CoreSize-L”,
and “CoreSize-H” respectively.
P2 ON/OFF P3 ON/OFF Preset Core Value Applied
OFF OFF WEB_04 Diam Preset 1
ON OFF WEB_05 Diam Preset 2
OFF ON WEB_06 Diam Preset 3
ON ON WEB_07 Diam Preset 4
WEB▶ Preset Src
03 Keypad
DIO▶ P1 define
01 Dia Preset
DIO▶ P2 define
02 CoreSize-L
DIO▶ P3 define
03 CoreSize-H