7. WEB Control Application
7-15
7.5.4 Function Group (FUN_[][])
If CON_02 Application of Control (CON) Group is selected as “WEB Control”, you may select the following function in
addition. For further detail, please refer to the explanation on WEB group function.
Definition of Function
Function
Code
Loader
Display
Name Setting Range
Unit Explanation of Function
Line SPD Ref
It is set when conducting line speed
command with analog input at the time of
Web control.
FUN_02 Spd Ref Sel
Speed Setting
Method
Line SPD Opt
It is set when conducting line speed
command with communication at the time of
Web control..
Note) In case of setting FUN_02 Spd Ref Sel to the other value than “Line SPD Ref” or “Line SPD Opt”,
you cannot make exact Web control. Therefore, please set “Line SPD Ref” or “Line SPD Opt” without fail.
7.5.5 Control Group (CON_[][])
CON_02 Application allows you the setting of general vector control mode and WEB control mode. In case of
conducting Web control, please set “WEB Control” without fail. Only when setting “WEB Control”, you
can confirm all the function and Web group necessary for WEB control in the keypad.
Definition of Function
Functio
nCode
Loader
Display
Name Setting Range
Unit Explanation of Function
General Vect It is set when using the general vector function.
CON_02 Application application control
WEB Control It is set when using Web control function.