4. Trial Operation
4-2
4.2 Keypad LCD Display
4.2.1 LCD Start-up display
No. Function Description
1 Motor speed Real motor speed in RPM (Revolution Per Minute)
2
Motor control Mode
SPD: Speed control mode
TRQ: Torque control mode
WEB: WEB control mode
BX: Emergency stop
BAT : Battery-operated mode
3 Generating torque Displays % ratio to the rated torque of a motor.
4 Output current Inverter output current in RMS
4.2.2 Group display
No. Function Description
1 Parameter group
Displays the name of each parameter group. There are DIS, DIO,
PAR, FUN, CON, AIO, USR and 2
nd
group.
2 Code name Displays a code name to be set.
3 Code Number Displays a code name to be set.
4 Code data and unit Displays a code data and a code unit to be set.
0.0rpm SPD
Tq 0.0% 0.0A
3 4
2 1
FUN Speed1
13 0.0rpm
3 4
2 1

Table of Contents