7. WEB Control Application
7-20
Initialization of Core by Analog Input Terminal
-. Initialization of Core by Analog Input Terminal requires setting of WEB_03 to “Analog” first.
-. Select one of multi-function input terminals (DIO_01 ~ DIO_07) and then set it to “Dia Preset”.
-. Select one of analog input terminal definitions (AIO_01, AIO_13, AIO_25), and then set it to “Diam Preset”.
-. You may initialize the diameter according to On/Off of multi-function input terminal set to “Dia Preset”. The
diameter value initialized, however, becomes the value of analog input terminal set, and it is restricted to
WEB_10 Min Diameter.
Example) Setting DIO_01 and AIO_01 to “Dia Preset” and “Diam Preset” respectively
Initialization of Core by Communication
-. Initialization of Core by Communication requires setting of WEB_03 to “Option” first.
-.Select one of multi-function input terminals (DIO_01 ~ DIO_07), and then set it to “Dia Preset”.
-.You may initialize the diameter according to On/Off of multi-function input terminal set to “Dia Preset”. The
diameter value initialized becomes the value of communication set, and is restricted to WEB_10 Min Diameter.
2) WEB_04 Diam Preset 1 : 1st diameter initial value
3) WEB_05 Diam Preset 2 : 2nd diameter initial value
4) WEB_06 Diam Preset 3 : 3rd diameter initial value
5) WEB_07 Diam Preset 4 : 4th diameter initial value
The diameter initialization in tension control (Diam Preset) means empty core at the time of winder operation,
while full core at the time of Unwinder operation. In case of initialize the core with multi-function input terminal, it
is set with one of WEB_04 Diam Preset 1 ~ WEB_07 Diam Preset 4 according to the WEB_04 Diam Preset 1 ~
WEB_07 Diam Preset 4 set to “CoreSize-L”and “CoreSize-H”. In case all the defined multi-function input terminals
are Off or are not set with the multi-function input, the initial value of diameter is set to “Diam Preset 1”. If
applying to bridle roll or nip roll instead of general winder and unwidner, you may set all the initial values to
100.0 %. In the core initialization using analog and communication, any initial value of WEB_04 Diam Preset 1 ~
WEB_07 Diam Preset 4 is not applied. The reference of the set value is the diameter initial value expressed in [%]
at the time of full diameter.
WEB Preset Src
03 Analog
AIO Ai1 Define
01 Diam Preset
DIO P1 define
01 Dia Preset

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LS Industrial Systems SV-iV5 Series and is the answer not in the manual?

LS Industrial Systems SV-iV5 Series Specifications

General IconGeneral
BrandLS Industrial Systems
ModelSV-iV5 Series
CategoryInverter
LanguageEnglish

Related product manuals