EasyManua.ls Logo

Lust CDA3000 - Page 334

Lust CDA3000
358 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-18
Application Manual CDA3000
Appendix B Error messages
12 E-PWR 6 Power pack not correctly detected Send in device . RESET
13 E-EXT 1 Error in an external device Rectify error in external device. STOP
15 E-OP1 150 Error in module at option slot 1 1. Check module and identifier; 2. (1) STOP
151
Error at option slot 2: BUS-OFF state
detected
Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
152
Error at option slot 2: Transmit protocol
could not be sent.
Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
153
Error at option slot 2: Module not responding Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
154
Error at option slot 2: Module has signalled
error.
Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
16 E-OP2 200 Error in module at option slot 2 1. Check module and identifier; 2. (1) STOP
201
Error on option 2: BUS-OFF state detected Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
202
Error on option 2: Transmit protocol could
not be sent.
Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
203
Error on option 2: Module not responding Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
204
Error on option 2: Module has signalled
error.
Check contacting of module. If the
error reoccurs after switching on/off,
the device or the module is faulty.
18 E-SIO
11
Watchdog monitoring communication over
LustBus tripped
1. Check connection; 2. Check bus
master or increase parameter SWDGT.
STOP
19 E-EEP 3 Error accessing parameter memory 1. Switch device off and back on; 2.(1) RESET
20 E-WBK
1
Possible wire break at input ISA01.
Current less than 4mA in parameter setting
to 4-20mA
Check wiring of input ISA01. STOP
Bus DM/KP
Error
location
no.
Error cause Possible remedy
Response
no.
in FS
(1) If this error is repeated please contact your local Service Partner.
Table A.2 Error messages of the CDA3000

Table of Contents