Application Manual CDA3000
A-19
Appendix B Error messages
1
2
3
4
5
6
A
DE
EN
FR
21 E-SC
20
Error in auto-tuning 1. Check motor wiring and repeat
process; 2. (1)
LOCK
21
Error in auto-tuning. Motor connected or
partially disconnected
1. Check motor wiring and repeat
process; 2. (1)
22
Auto-tuning is suitable only for asynchro-
nous machines. \n
Set parameter 153-CFMOT to ASM if
a relevant motor is being used and
repeat auto-tuning.
23
Auto-tuning is unable to identify the con-
nected motor correctly. \n
1. Get motor parameters from manu-
facturer and enter manually; 2. If pos-
sible use another motor.
22 E-PF
1
Error in power failure bridging: The DC-link
voltage was not restored within the preset
time (parameter 343-PFTIM).
Check mains power supply. STOP
23 E-RM
0
Error in activation of an application data set 1. The error location number identifies
the incorrect parameter; 2. (1)
RESET
24 E-FDG 1 Transmission error in reference coupling Check connection. STOP
25 E-LSW 1 Limit switches reversed Correct wiring. LOCK
Bus DM/KP
Error
location
no.
Error cause Possible remedy
Response
no.
in FS
(1) If this error is repeated please contact your local Service Partner.
Table A.2 Error messages of the CDA3000