13.15 Sequencer Control 125
SequencerTriggerSource sequencerTriggerSource Specifies the internal signal or
physical input line to use as the
sequencer trigger source. Value
supported by MATRIX VISION
devices are:
Off: Disables the sequencer
trigger.
ExposureEnd: Starts with
the reception of the Expo-
sure End.
Counter1End: Starts with
the reception of the Counter
1 End.
Other possible values that might
be supported by third party devices
are:
AcquisitionTrigger: Starts
with the reception of the
Acquisition Trigger.
AcquisitionTriggerMissed:
Starts with the reception
of the missed Acquisition
Trigger.
AcquisitionStart: Starts with
the reception of the Acquisi-
tion Start.
AcquisitionEnd: Starts with
the reception of the Acquisi-
tion End.
FrameTrigger: Starts with
the reception of the Frame
Start Trigger.
FrameTriggerMissed: Starts
with the reception of the
missed Frame Trigger.
FrameStart: Starts with the
reception of the Frame Start.
FrameEnd: Starts with the
reception of the Frame End.
FrameBurstStart: Starts with
the reception of the Frame
Burst Start.
FrameBurstEnd: Starts with
the reception of the Frame
Burst End.
ExposureStart: Starts with
the reception of the Expo-
sure Start.
Line0 (If 0 based), Line1,
Line2, ...: Starts when the
specified TimerTrigger-
Activation condition is met
on the chosen I/O Line.
UserOutput0, UserOutput1,
UserOutput2, ...: Specifies
which User Output bit signal
to use as internal source for
the trigger.
Counter0Start, Counter1-
Start, Counter2Start, ...:
Starts with the reception of
the Counter Start.
Counter0End, Counter1End,
Counter2End, ...: Starts with
the reception of the Counter
End.
Timer0Start, Timer1Start,
Timer2Start, ...: Starts with
the reception of the Timer
Start.
Timer0End, Timer1End,
Timer2End, ...: Starts with
the reception of the Timer
End.
Encoder0, Encoder1, En-
coder2, ...: Starts with the
reception of the Encoder
output signal.
LogicBlock0, LogicBlock1,
LogicBlock2, ...: Starts with
the reception of the Logic
Block output signal.
SoftwareSignal0,
SoftwareSignal1,
SoftwareSignal2, ...-
: Starts on the reception of
the Software Signal.
Action0, Action1, Action2,
...: Starts with the assertion
of the chosen action signal.
LinkTrigger0, LinkTrigger1,
LinkTrigger2, ...: Starts with
the reception of the chosen
Link Trigger.
CC1, CC2, CC3, CC4: Index
of the Camera Link physical
line and associated I/O con-
trol block to use. This en-
sures a direct mapping be-
tween
MATRIX VISION GmbH

Table of Contents