Using the RFID Functions 133
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual LOGIJET T4 /T6 /RFID Edition 1.3
Panel display
Explanations, Remedies
[RFID Error ]
[ID Read TimeOut ]
The read command has failed to complete in the
maximum amount of allowed time.
The RFID tag was not found in the RF Field (area
inside the printer where RFID tag is read)
or
the RFID tag was found in the RF Field, but
could not be read.
- check supply loading
- if you made supply or print position settings,
make sure the RFID tag was not moved out of
the readable range.
- see section 8.2.3 Adjusting the Transponder
Position, too.
- check the communication protocol setting
See section 8.2.2 Selecting the
Communication Protocol.
- increase the number of retries
See section 8.2.4 Adjusting the Number of
RFID Access.

Table of Contents