OMNIScanner User Guide
A - 2
OMNI
Fiber
MM LED Displays
• 850 nm Indicator (GREEN) for transmitting at 850 nm
• 1300 nm Indicator (GREEN) for transmitting at 1300 nm
• 850 nm Indicator (ORANGE) for switching fibers
• 1300 nm Indicator (ORANGE) for switching fibers
OMNI
Fiber
SM LED Displays
• 1310 nm Indicator (GREEN) for transmitting at 1310 nm
• 1550 nm Indicator (GREEN) for transmitting at 1550 nm
• 1310 nm Indicator (ORANGE) for switching fibers
• 1550 nm Indicator (ORANGE) for switching fibers
Power
• Removable, rechargeable battery pack
• 9.6 Volts @ 1200 mA-Hr Ni-Cd
• 9.6 Volts @ 1900 mA-Hr NiMH (OMNI
Scanner
2)
• Built-in fast charger using AC adapter
• Charging Time: 3½ hours for fully discharged batteries.
• Battery life : 10+ hours operation (typical)
• AC: 15 VDC - 1 amp AC adapter for continuous operation or charging
Environmental
• Operating Temperature: 0°C to 50°C (32°F to 122°F)
• Storage Temperature: -10°C to 55°C (14°F to 131°F)
• Operating Humidity: (non-condensing): 5% to 90%
• Storage Humidity: 5% to 95%
• Regulatory Compliance: CE Class A
Measurement Port (Test Interface)
• Ultra low Crosstalk test interface that supports testing of all four pairs
• 160 pin test interface connector which exceeds 10,000 mating cycles
• Variety of test cables and adapter modules support testing of 110 block
and shielded modular jack and plug interfaces
Serial Port
• Connector: DB-9
• Baud Rate: 300 to 57,600 baud
• Parity: None
• Length: 8 Bits
• Handshaking: None, RTS/CTS, and XON/XOFF