© 2014 MIMAKI ENGINEERING CO.,LTD.
4.2.13 P.1
1
2
3
4
5
6
7
8
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > FEED COMP.2
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver.
1.00
Remark
1.0
Rev.
R.1.0
4.2.13FEED COMP.2
Function
Compensates basic feeding amount of media. (Provides a baseline value for user compensation value.)
Is used to adjust the media feed amount when the parameter has been initialized or user compensation value is too large.
Procedure
1. Select [#ADJUST] - [FEED COMP.2].
2. Draw an adjustment pattern.
[ENTER]: Executes drawing.
[]: To the screen for adjustment
(Without drawing)
[END]: Completes drawing and inputs compensation
value.
3. Check the adjustment pattern.
4. Enter the compensation value.
Compensation value: -9999 to 9999
[]/[]: Changes adjustment values.
[END]: Cancellation of input
FUNCTION
#ADJUST [ENT]
#ADJUST
FEED COMP.2 [ENT]
#FEED COMP.2
PRINT START [ENT]
Pattern drawing
Patterns are plotted repeatedly.
(Click [END] to end plotting.)
A pattern having width
of media is drawn.
Resolution is 720 dpi.
Compensation value is
too large.
Compensation value is
too small.
#FEED COMP.2
ADJUST = 0
In actual feeding amount compensation, compensation
value for each media set in the SETUP function are
added to this compensation value.