EasyManua.ls Logo

MIMAKI CJV150-107 - 6.5.3 NCU Assy. (Nozzle Missing Detector)

MIMAKI CJV150-107
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2014 MIMAKI ENGINEERING CO.,LTD. 6.5.3 P.1
1
2
3
4
5
6
7
8
6.5.3 NCU Assy. (Nozzle Missing Detector)
Work procedures
1. Turn the main power OFF.
2. Remove the Front cover M.
3. Move slowly the carriage onto the platen by hand.
4. Remove the NCU absorber tray. (take off a hook).
5. Disconnect the all connectors.
6. Remove screws (x2) on the NCU frame, and then remove the
NCU Assy.
7. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
NCU absorber tray
NCU Assy.
Adjustment screw
Press against the adjustment screw and affix.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > NCU Assy. (Nozzle Missing Detector)
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0
Rev.

Table of Contents

Other manuals for MIMAKI CJV150-107

Related product manuals