© 2014 MIMAKI ENGINEERING CO.,LTD.
6.3.11 P.1
1
2
3
4
5
6
7
8
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > GR Roller Assy
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver. Remark
1.0
6.3.11 GR Roller Assy
Work procedures
1. Remove the connector of pre-heater and print heater and then
remove the platen cover R-C160 and platen cover 160-C-2.
2. Loosen all PF coupling C set screws. (x8)
After turning off the sub and main power switches, unplug the power cord. Make sure to take15 minutes
before restarting the operation.
It is very dangerous if sleep mode functions mistakenly during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of the PCBs. Take care to avoid contact with it.
PF Coupling C
Loosen