Outline
This function is capable of confirming sensor sensitivity, degree of tilting condition and discharge position of NCU
(Nozzle missing detector unit).
Work procedure
Sensor check
1. Select [#TEST]-[SENSOR CHECK].
[]/[]: Select
[ENTER]: Confirmation
Press [ENTER] key.
2. Change display with [ENTER] key.
Not change the numerical values.
3. The number in the left figure is alight more than “130”.
In case that number is less than “130”, replace the NCU unit.
Adjustment for tilting
4. Select [SLANT ADJUST].
[]/[]: Select
[ENTER]: Confirmation
Press [ENTER] key.
5. Confirm 4 numbers in the left figure.
・Must be numerals other than “999”. (Example: -7. -7. -2. -2)
・Take the numerals to be, in left-to-right order: “ ① , ① ', ② ,
② ' ”.
① - ① ' (the difference between ① and ① ') and ② - ② '
(the difference between ② and ② ') must be no more than 5.
If the two conditions above are satisfied, the NCU unit is not
tilting (does not need adjustment).
#TEST
NCU [ENT]
#NCU
SENSOR
CHECK [ENT]
CHECK
LIGHTVOL
= 125
SENSCHECKTHD
= 130
NUMBEROFEXE.
= 10
#NCU
Value:190
Confirm a number
More than 130 is OK
The number indicate sensor sensitivity of the NCU
unit.
#NCU
#SLANTADJUST [ENT]
#NCU
999.999.999.999
Confirm 4 numbers
・Non-999
・① - ① '<± 5 and
② - ② '<± 5 is OK
① ① ' ② ② '
In case of 150 series (one head machine);
Confirm ① -①' (the difference between ① and ①')
must be no more than 5 because only ① and ① ' are
performed scanning (display of ② and ② ' are not
changed).
MAINTENANCE MANUAL > Test Items > Test Function > NCU
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark