© 2014 MIMAKI ENGINEERING CO.,LTD. 6.4.11 P.1
1
2
3
4
5
6
7
8
6.4.11 Ceiling Drying Fan Assy.
Work procedures
1. Remove the connector.
2. Push up the stoppers at bottom of the cover, and then remove
the Assy. together with cover.
3. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
Ceiling drying fan Assy x5(160 size), x4(130 size)
Optional part for 150 series
When attaching, push down the stopper and fix the
Assy. It is not fixed only by having fitted it.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Ceiling Drying Fan Assy.
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0